- Overview
- Specifications
- Detailed Photos
- Dimension
- Packaging & Shipping
Basic Info.
Model NO.
MF-QCD-H300
Operating Voltage
220-240V
Input Voltage
100-305VAC
LED Chips Brand
SMD2835/SMD3030
Luminous Flux (Lm)
150llm/W-170lm/W
Working Temperature
-30°c- +50°c
PF
>0.95
Power Efficiency
0.90
CRI
70ra/80ra/90ra
Material
Die-Cast Aluminum
CCT
3000K-5700K
Ik Rating
Ik08
Beam Angle
10°/25°/45°/60&Deg/90&Deg/65&Deg*25&De
Lifespan
50,000hrs
Warranty Period
5 Years
Transport Package
1PCS/Carton Box
Trademark
MF
Origin
China
HS Code
9405499000
Production Capacity
10000PCS Per Months
Product Description
Factory Price 250W/500W/750W/1000W/1250W IP66 IK08 High Mast Light 150LM/W 3000K/4000K/5000K/5700K CRI80 Stadium Light For Soccer Field
Lighting infrastructure is a strategic resource in modern stadium. LED lighting not just simply means energy saving, environmental protection, reducing installation job, and reducing subsequent maintenance cost. More importantly, it offers new oppirtunities for the stadium. Different lighting demand can be realized through intelligent control, making the stadium being a multi-functional venue which is capable of holding large scale events, such as concert.
1. Fan enthusiasm is the core part of a contest. Fan's emotion and atmosphere can be stimulated by pre-game and post-game entertainment activities, which will increase time that fans stay in the stadium.
2. Contestants need comfortable light free from glare to reduce reaction time and avoid mistakes, so that they will surpass at an exceeding level. In addition, for soprts such as football, both the vertical and horizontal directions must ensure perfect illumination.
3. LEDs with TLCI>90 is adopted, which can meet the HD camera's requirement to broadcast. DC dimming program is used to achieve flicker- free effect and slow motion replay demand.
4. Lighting inside the stadium is the central part of modern stadium lighting. Superman two series can effectively reduce glare through muttiple anti-glare design, allowing player to have upgrading.
5. Beside lighting inside the stadium, lighting outside the stadium is required to improve as well. MF Lighting has corresponding product series for selections.
6. Large stadium can accommodate tens of thousands of spectators. MF Lighting is available for floodlight, sports light, tunnel light, high mast high products.
Main Accessories:
EXCELLENT HEAT DISSIPATION AND LIFE-SPAN ASSURED
The lifespan and reliability of LED fixtures largely depend on thermal management system which includes three passive cooling methods, conduction, radiation and convection . Die-casting module design increases heat dissipation areas and conduction area. It is much more conductive to heat dissipation, performance and lifespan.
Conduction:
Thermal conduction refers to a type of heat dissipation method in which the heat of the body is directly transferred to the lower temperature object in contact with it.
Radiation:
Radiation is a heat transfer method in which the heat source is radiated in a straightline in all directions, and at the same time absorbs the energy back reflected by the surrounding objects. The radiation ability of an object (ie, the energy radiated outward from a unit surface per unit time) increases rapidly with increasing temperature. Superman series achieves better heat dissipation capacity by continuously optimizing and increasing the heat dissipation areas, LED heat is transferred to the heat sink through thermally con ductive silicone.
Convection:
Thermal convection means that the air temperature rises due to the radiation, and the volume expands and rises. The cold air is then replenished, and the heat dissipation surface exchanges heat with the newly moved cooler air, thus continuously taking away the heat. As for superman series, each model has an extended fin design to achieve convection.
Beam Spread:
Application Fields:
What are the advantages of our product:
The new generation in LED soprts & area lighting, create an unbelievable
combination of world-class performance, energy saving, cutting-edge optical & thermal management technology and ongoing low maintenance cost in one sleek package solution.
1. All-in-one design to perform
2. Flicker-free/slow motion replay
3. Modular design concept
4. Low wind resistance, high protection.
5. Cutting- eadg thermal management system
6.Spill light-free
7. Glare-free
8. High corrosion & Rust ressistant
The new generation in LED soprts & area lighting, create an unbelievable
combination of world-class performance, energy saving, cutting-edge optical & thermal management technology and ongoing low maintenance cost in one sleek package solution.
1. All-in-one design to perform
2. Flicker-free/slow motion replay
3. Modular design concept
4. Low wind resistance, high protection.
5. Cutting- eadg thermal management system
6.Spill light-free
7. Glare-free
8. High corrosion & Rust ressistant
Lighting infrastructure is a strategic resource in modern stadium. LED lighting not just simply means energy saving, environmental protection, reducing installation job, and reducing subsequent maintenance cost. More importantly, it offers new oppirtunities for the stadium. Different lighting demand can be realized through intelligent control, making the stadium being a multi-functional venue which is capable of holding large scale events, such as concert.
1. Fan enthusiasm is the core part of a contest. Fan's emotion and atmosphere can be stimulated by pre-game and post-game entertainment activities, which will increase time that fans stay in the stadium.
2. Contestants need comfortable light free from glare to reduce reaction time and avoid mistakes, so that they will surpass at an exceeding level. In addition, for soprts such as football, both the vertical and horizontal directions must ensure perfect illumination.
3. LEDs with TLCI>90 is adopted, which can meet the HD camera's requirement to broadcast. DC dimming program is used to achieve flicker- free effect and slow motion replay demand.
4. Lighting inside the stadium is the central part of modern stadium lighting. Superman two series can effectively reduce glare through muttiple anti-glare design, allowing player to have upgrading.
5. Beside lighting inside the stadium, lighting outside the stadium is required to improve as well. MF Lighting has corresponding product series for selections.
6. Large stadium can accommodate tens of thousands of spectators. MF Lighting is available for floodlight, sports light, tunnel light, high mast high products.
Plan A 150lm/w
Model No. | MF-QCD-H250W | MF-QCD-H500W | MF-QCD-H750W | MF-QCD-H1000W | MF-QCD-H1250W |
Light Source | 440*PCT2835 126*SMD3737 | 880*PCT2835 252*SMD3737 | 1320*PCT2835 378*SMD3737 | 1760*PCT2835 504*SMD3737 | 2200*PCT2835 563*SMD3737 |
Driver Brand | MW/SOSEN | MW/SOSEN | MW/SOSEN | MW/SOSEN | MW/SOSEN |
Rated Power (W) | 240W | 480W | 720W | 960W | 1200W |
Input Voltage (V) | 100-305Vac 50/60Hz | 100-305Vac 50/60Hz | 100-305Vac 50/60Hz | 100-305Vac 50/60Hz | 100-305Vac 50/60Hz |
output Voltage (V) | 48 | 48 | 48 | 48 | 48 |
Power Factor | >0.95 | >0.95 | >0.95 | >0.95 | >0.95 |
THD | <10 | <10 | <10 | <10 | <10 |
Luminous Flux (lm) | 36000±5% | 72000±5% | 10800±5% | 144000±5% | 180000±5% |
CCT (K) | 3000/4000/5000/5700 | 3000/4000/5000/5700 | 3000/4000/5000/5700 | 3000/4000/5000/5700 | 3000/4000/5000/5700 |
CRI (Ra) | >70/>80/>90 | >70/>80/>90 | >70/>80/>90 | >70/>80/>90 | >70/>80/>90 |
Beam Angle | 10°/25°/45°/60°/ 90°/65*25° | 10°/25°/45°/60°/ 90°/65*25° | 10°/25°/45°/60°/ 90°/65*25° | 10°/25°/45°/60°/ 90°/65*25° | 10°/25°/45°/60°/ 90°/65*25° |
IP Class | IP66 | IP66 | IP66 | IP66 | IP66 |
IK Class | IK08/IK10 | IK08/IK10 | IK08/IK10 | IK08/IK10 | IK08/IK10 |
Outer Carton (mm) | 630*330*230 | 630*520*230 | 630*680*230 | 630*840*230 | 630*1000*230 |
Net Weight (kgs) | 7 | 14 | 20 | 26 | 32 |
Gross Weight (kgs) | 7.5 | 15 | 22 | 28 | 35 |
Plan B 170lm/w
Model No. | MF-QCD-H250W | MF-QCD-H500W | MF-QCD-H750W | MF-QCD-H1000W | MF-QCD-H1250W |
Light Source | 440*SMD2835 126*SMD3737 | 880*SMD2835 252*SMD3737 | 1320*SMD2835 378*SMD3737 | 1760*SMD2835 504*SMD3737 | 2200*SMD2835 563*SMD3737 |
Driver Brand | MW/SOSEN | MW/SOSEN | MW/SOSEN | MW/SOSEN | MW/SOSEN |
Rated Power (W) | 240W | 480W | 720W | 960W | 1200W |
Input Voltage (V) | 100-305Vac 50/60Hz | 100-305Vac 50/60Hz | 100-305Vac 50/60Hz | 100-305Vac 50/60Hz | 100-305Vac 50/60Hz |
output Voltage (V) | 48 | 48 | 48 | 48 | 48 |
Power Factor | >0.95 | >0.95 | >0.95 | >0.95 | >0.95 |
THD | <10 | <10 | <10 | <10 | <10 |
Luminous Flux (lm) | 40800±5% | 81600±5% | 12240±5% | 163200±5% | 204000±5% |
CCT (K) | 3000/4000/5000/5700 | 3000/4000/5000/5700 | 3000/4000/5000/5700 | 3000/4000/5000/5700 | 3000/4000/5000/5700 |
CRI (Ra) | >70/>80/>90 | >70/>80/>90 | >70/>80/>90 | >70/>80/>90 | >70/>80/>90 |
Beam Angle | 10°/25°/45°/60°/ 90°/65*25° | 10°/25°/45°/60°/ 90°/65*25° | 10°/25°/45°/60°/ 90°/65*25° | 10°/25°/45°/60°/ 90°/65*25° | 10°/25°/45°/60°/ 90°/65*25° |
IP Class | IP66 | IP66 | IP66 | IP66 | IP66 |
IK Class | IK08/IK10 | IK08/IK10 | IK08/IK10 | IK08/IK10 | IK08/IK10 |
Outer Carton (mm) | 630*330*230 | 630*520*230 | 630*680*230 | 630*840*230 | 630*1000*230 |
Net Weight (kgs) | 7 | 14 | 20 | 26 | 32 |
Gross Weight (kgs) | 7.5 | 15 | 22 | 28 | 35 |
Plan C 150lm/w
Model No. | MF-QCD-H300W | MF-QCD-H600W | MF-QCD-H900W | MF-QCD-H1200W | MF-QCD-H1500W |
Light Source | 440*SMD2835 126*SMD3737 | 880*SMD2835 252*SMD3737 | 1320*SMD2835 378*SMD3737 | 1760*SMD2835 504*SMD3737 | 2200*SMD2835 563*SMD3737 |
Driver Brand | MW/SOSEN | MW/SOSEN | MW/SOSEN | MW/SOSEN | MW/SOSEN |
Rated Power (W) | 300W | 600W | 900W | 1200W | 1500W |
Input Voltage (V) | 100-305Vac 50/60Hz | 100-305Vac 50/60Hz | 100-305Vac 50/60Hz | 100-305Vac 50/60Hz | 100-305Vac 50/60Hz |
output Voltage (V) | 48 | 48 | 48 | 48 | 48 |
Power Factor | >0.95 | >0.95 | >0.95 | >0.95 | >0.95 |
THD | <10 | <10 | <10 | <10 | <10 |
Luminous Flux (lm) | 45000±5% | 90000±5% | 13500±5% | 180000±5% | 225000±5% |
CCT (K) | 3000/4000/5000/5700 | 3000/4000/5000/5700 | 3000/4000/5000/5700 | 3000/4000/5000/5700 | 3000/4000/5000/5700 |
CRI (Ra) | >70/>80/>90 | >70/>80/>90 | >70/>80/>90 | >70/>80/>90 | >70/>80/>90 |
Beam Angle | 10°/25°/45°/60°/ 90°/65*25° | 10°/25°/45°/60°/ 90°/65*25° | 10°/25°/45°/60°/ 90°/65*25° | 10°/25°/45°/60°/ 90°/65*25° | 10°/25°/45°/60°/ 90°/65*25° |
IP Class | IP66 | IP66 | IP66 | IP66 | IP66 |
IK Class | IK08/IK10 | IK08/IK10 | IK08/IK10 | IK08/IK10 | IK08/IK10 |
Outer Carton (mm) | 630*330*230 | 630*520*230 | 630*680*230 | 630*840*230 | 630*1000*230 |
Net Weight (kgs) | 7 | 14 | 20 | 26 | 32 |
Gross Weight (kgs) | 7.5 | 15 | 22 | 28 | 35 |
Main Accessories:
EXCELLENT HEAT DISSIPATION AND LIFE-SPAN ASSURED
The lifespan and reliability of LED fixtures largely depend on thermal management system which includes three passive cooling methods, conduction, radiation and convection . Die-casting module design increases heat dissipation areas and conduction area. It is much more conductive to heat dissipation, performance and lifespan.
Conduction:
Thermal conduction refers to a type of heat dissipation method in which the heat of the body is directly transferred to the lower temperature object in contact with it.
Radiation:
Radiation is a heat transfer method in which the heat source is radiated in a straightline in all directions, and at the same time absorbs the energy back reflected by the surrounding objects. The radiation ability of an object (ie, the energy radiated outward from a unit surface per unit time) increases rapidly with increasing temperature. Superman series achieves better heat dissipation capacity by continuously optimizing and increasing the heat dissipation areas, LED heat is transferred to the heat sink through thermally con ductive silicone.
Convection:
Thermal convection means that the air temperature rises due to the radiation, and the volume expands and rises. The cold air is then replenished, and the heat dissipation surface exchanges heat with the newly moved cooler air, thus continuously taking away the heat. As for superman series, each model has an extended fin design to achieve convection.
Beam Spread:
Application Fields: